71 research outputs found
Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
We present an experimental study of single electron emission in ZEPLIN-III, a
two-phase xenon experiment built to search for dark matter WIMPs, and discuss
applications enabled by the excellent signal-to-noise ratio achieved in
detecting this signature. Firstly, we demonstrate a practical method for
precise measurement of the free electron lifetime in liquid xenon during normal
operation of these detectors. Then, using a realistic detector response model
and backgrounds, we assess the feasibility of deploying such an instrument for
measuring coherent neutrino-nucleus elastic scattering using the ionisation
channel in the few-electron regime. We conclude that it should be possible to
measure this elusive neutrino signature above an ionisation threshold of
3 electrons both at a stopped pion source and at a nuclear reactor.
Detectable signal rates are larger in the reactor case, but the triggered
measurement and harder recoil energy spectrum afforded by the accelerator
source enable lower overall background and fiducialisation of the active
volume
Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator
Plastic scintillators are widely used in industry, medicine and scientific
research, including nuclear and particle physics. Although one of their most
common applications is in neutron detection, experimental data on their
response to low-energy nuclear recoils are scarce. Here, the relative
scintillation efficiency for neutron-induced nuclear recoils in a
polystyrene-based plastic scintillator (UPS-923A) is presented, exploring
recoil energies between 125 keV and 850 keV. Monte Carlo simulations,
incorporating light collection efficiency and energy resolution effects, are
used to generate neutron scattering spectra which are matched to observed
distributions of scintillation signals to parameterise the energy-dependent
quenching factor. At energies above 300 keV the dependence is reasonably
described using the semi-empirical formulation of Birks and a kB factor of
(0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured
quenching factor falls more steeply than predicted by the Birks formalism.Comment: 8 pages, 9 figure
WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
We report experimental upper limits on WIMP-nucleon elastic scattering cross
sections from the second science run of ZEPLIN-III at the Boulby Underground
Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days
of continuous operation between June 2010 and May 2011. A total of eight events
was observed in the signal acceptance region in the nuclear recoil energy range
7-29 keV, which is compatible with background expectations. This allows the
exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass
with 90% confidence. Combined with data from the first run, this result
improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent
cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its
conclusion at Boulby, having deployed and exploited successfully three liquid
xenon experiments of increasing reach
Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses
a 12kg two-phase xenon time projection chamber to search for the weakly
interacting massive particles (WIMPs) that may account for the dark matter of
our Galaxy. The detector measures both scintillation and ionisation produced by
radiation interacting in the liquid to differentiate between the nuclear
recoils expected from WIMPs and the electron recoil background signals down to
~10keV nuclear recoil energy. An analysis of 847kg.days of data acquired
between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon
elastic scattering spin-independent cross-section above 8.1x10(-8)pb at
55GeV/c2 with a 90% confidence limit. It has also demonstrated that the
two-phase xenon technique is capable of better discrimination between electron
and nuclear recoils at low-energy than previously achieved by other xenon-based
experiments.Comment: 12 pages, 17 figure
The Tevatron at the Frontier of Dark Matter Direct Detection
Direct detection of dark matter (DM) requires an interaction of dark matter
particles with nucleons. The same interaction can lead to dark matter pair
production at a hadron collider, and with the addition of initial state
radiation this may lead to mono-jet signals. Mono-jet searches at the Tevatron
can thus place limits on DM direct detection rates. We study these bounds both
in the case where there is a contact interaction between DM and the standard
model and where there is a mediator kinematically accessible at the Tevatron.
We find that in many cases the Tevatron provides the current best limit,
particularly for light dark matter, below 5 GeV, and for spin dependent
interactions. Non-standard dark matter candidates are also constrained. The
introduction of a light mediator significantly weakens the collider bound. A
direct detection discovery that is in apparent conflict with mono-jet limits
will thus point to a new light state coupling the standard model to the dark
sector. Mono-jet searches with more luminosity and including the spectrum shape
in the analysis can improve the constraints on DM-nucleon scattering cross
section.Comment: 20 pages, 8 figures, final version in JHE
The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.Comment: 25 pages, 19 figures. Submitted to Astropart. Phys. Some figures down
sampled to reduce siz
nanoparticles production and inclusion in s aureus incubated with polyurethane an electron microscopy analysis
This study shows that submicron/nanoparticles found in bacterial cells (S. aureus) incubated with polyurethane (a material commonly used for prostheses in odontostomatology) are a consequence of biodestruction. The presence of polyurethane nanoparticles into bacterial vesicles suggests that the internalization process occurs through endocytosis. TEM and FIB/SEM are a suitable set of correlated instruments and techniques for this multi facet investigation: polyurethane particles influence the properties of S. aureus from the morpho-functional standpoint that may have undesirable effects on the human body. S. aureus and C. albicans are symbiotic microorganisms; it was observed that C. albicans has a similar interaction with polyurethane and an increment of the biodestruction capacity is expected by its mutual work with S. aureus
Performance data from the ZEPLIN-III second science run
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the
Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an
array of low background photomultipliers, a new anti-coincidence detector
system with plastic scintillator and an improved calibration system. After 319
days of data taking the second science run ended in May 2011. In this paper we
describe the instrument performance with emphasis on the position and energy
reconstruction algorithm and summarise the final science results.Comment: Submitted to PSD9 conference proceeding
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
We studied the application of statistical reconstruction algorithms, namely
maximum likelihood and least squares methods, to the problem of event
reconstruction in a dual phase liquid xenon detector. An iterative method was
developed for in-situ reconstruction of the PMT light response functions from
calibration data taken with an uncollimated gamma-ray source. Using the
techniques described, the performance of the ZEPLIN-III dark matter detector
was studied for 122 keV gamma-rays. For the inner part of the detector (R<100
mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the
horizontal plane for primary and secondary scintillation, respectively. An
energy resolution of 8.1% FWHM was achieved at that energy. The possibility of
using this technique for improving performance and reducing cost of
scintillation cameras for medical applications is currently under study.Comment: 8 pages, 7 figures, in the Conference Record of IEEE NSS 2011,
accepted for publication in IEEE Trans. on Nuc. Sc
- …